Description
The AniSurg BAM-5 Pro Turbo Veterinary Anesthesia Ventilator is a cutting-edge, turbine-driven ventilation solution engineered exclusively for animal care—designed to meet the needs of veterinary hospitals, animal clinics, research institutions, wildlife rescue stations, and academic laboratories. Developed by AniSurg, this premium ventilator stands out with its innovative turbine-driven technology that eliminates the need for external gas sources, offering unmatched convenience and flexibility. Compatible with animals up to 100kg (including rabbits, cats, dogs, monkeys, pigs, sheep, etc.), it seamlessly integrates with all international standard veterinary anesthesia machines, providing safe, precise mechanical ventilation during surgeries, anesthesia, and critical care. With a 9-inch high-definition touchscreen, auto-parameter calculation, and comprehensive safety features, the BAM-5 Pro Turbo redefines efficiency and reliability in animal ventilation, making it the ideal choice for modern veterinary practices seeking advanced, user-friendly solutions.
Core Product Advantages (Highlighting Turbine-Driven Superiority)
Turbine-Driven Design – No External Gas Required
The BAM-5 Pro Turbo ’s standout feature is its turbine-driven and electronic control system, which eliminates the need for external gas source connections. This innovative design not only saves space in clinics and labs but also reduces gas source costs and operational complexity. Unlike pneumatic-driven alternatives (e.g., BAM-5 Pro), the turbine converts ambient air into drive gas on-demand, ensuring consistent ventilation performance regardless of external gas availability. This makes the BAM-5 Pro Turbo highly portable and suitable for field applications like wildlife rescue, mobile veterinary services, or facilities with limited gas infrastructure—delivering zero oxygen consumption and reliable operation in diverse environments.
Comprehensive Multi-Mode Ventilation for All Scenarios
Equipped with a full suite of ventilation modes, the BAM-5 Pro Turbo adapts to diverse animal conditions and clinical needs: Volume-Controlled Ventilation (VCV), Pressure-Controlled Ventilation (PCV), Spontaneous (SPONT) mode, Synchronized Intermittent Mandatory Ventilation (SIMV), Manual mode, and Demo mode. The SPONT mode intelligently avoids breathing confrontation, providing auto-ventilation when animals have no spontaneous breathing, while VCV and PCV modes ensure precise control over tidal volume and airway pressure. This versatility covers everything from routine surgical anesthesia to critical care ventilation, meeting the demands of small pets, large livestock, and research animals.
Intuitive Operation & Smart Parameter Automation
The 9-inch high-definition TFT touchscreen offers clear visualization of key parameters, waveforms, and system status—paired with a shuttle knob for easy adjustment and a lock screen function to prevent accidental touches. A standout user-friendly feature: simply input the animal’s weight, and the ventilator automatically calculates and sets optimal tidal volume, breathing rate, I:E ratio, and other critical parameters. This reduces reliance on operator experience, streamlines workflow, and ensures consistent, safe ventilation for animals of all sizes. Additionally, the USB software upgrade interface allows for convenient function expansion and system updates.
Dual Bellows & Wide Parameter Range for Universal Compatibility Designed with dual-sized bellows (0-300ml for small animals, 300-1500ml for large animals), the BAM-5 Pro Turbo offers a wide tidal volume range (20-1500ml) with both coarse and fine adjustments, ensuring precise ventilation for animals from small rodents to 100kg livestock. Key parameters are fully adjustable to meet species-specific needs: breathing rate (1-150 BPM), I:E ratio (9.9:1~1:9.9), airway pressure (2-60 cmH2O), PEEP (0-20 cmH2O), and inspiratory time (0.1-12s). The ventilator also features proximal respiratory flow monitoring for enhanced accuracy, ensuring reliable data for clinical decision-making.
Advanced Safety Features & Reliable Performance Safety is prioritized with a 3-level color-coded audible-visual alarm system covering over 20 alarm events (e.g., high/low pressure, high/low tidal volume, low drive gas pressure, low battery, apnea). The apnea alarm (adjustable 3-20 seconds) and LED airway pressure alarm with automatic pressure relief protect animals from airway overpressure and respiratory risks. A built-in cooling fan system prevents overheating during prolonged use, while the integrated lithium battery provides 2-4 hours of backup power in case of power failure—ensuring uninterrupted ventilation. The BAM-5 Pro Turbo also holds ISO13485 and CE certifications, with a 36-month super-long warranty, guaranteeing long-term reliable performance.
Key Differences Between BAM-5 Pro Turbo and BAM-5 Pro
| Comparison Dimension | BAM-5 Pro Turbo (Turbine-Driven) | BAM-5 Pro (Pneumatic-Electric Driven) |
| Driving Technology | Turbine-driven + electronic control; no external gas source required | Pneumatic + electronic control; requires external gas source connection |
| Core Advantage | Portable, space-saving, zero oxygen consumption; ideal for field/mobile use | Dependent on stable external gas supply; suitable for fixed clinic/lab settings |
| Operational Flexibility | High (no gas infrastructure constraints) | Limited (requires gas source setup and maintenance) |
| Cost Efficiency | Lower long-term costs (no gas supply expenses) | Higher long-term costs (ongoing gas source consumption) |
| Target Scenarios | Wildlife rescue, mobile veterinary services, research labs, clinics with limited space | Fixed veterinary hospitals, large clinics, labs with stable gas infrastructure |
| Other Differences | Identical core features (modes, parameters, screen, safety functions) | Identical core features (modes, parameters, screen, safety functions) |
| Specification Category | Parameter Details |
| Product Model | AniSurg BAM-5 Pro Turbo Veterinary Anesthesia Ventilator |
| Driving Mode | Turbine-driven + electronic control (no external gas source required) |
| Working Modes | Auto-control, Manual |
| Ventilation Modes | VCV (Volume-Controlled Ventilation), PCV (Pressure-Controlled Ventilation), SPONT (Spontaneous), SIMV (Synchronized Intermittent Mandatory Ventilation), Manual, Demo |
| Applicable Animal Weight | Up to 100kg (rabbits, cats, dogs, monkeys, pigs, sheep, etc.) |
| Bellows Configuration | Dual bellows: 0-300ml (small animals), 300-1500ml (large animals) |
| Key Ventilation Parameters | – Tidal Volume (TV): 20-1500ml- Breathing Rate (Freq): 1-150 BPM- I:E Ratio: 9.9:1~1:9.9- Inspiratory Time (T_Insp): 0.1-12s- Airway Pressure (PInsp): 2-60 cmH2O- PEEP: 0-20 cmH2O- SIMV Frequency (F_SIMV): 2-60 BPM- Pressure Support (PS): 0-60 cmH2O- Flow Trigger Sensitivity (F_Trig): 0.5-20 L/min, OFF- Pressure Trigger Sensitivity (P_Trig): -1~-20 cmH2O, OFF |
| Monitoring Parameters | Tidal volume (inspiratory/expiratory), minute ventilation (MV/MV_Spont), peak pressure (Ppeak), platform pressure (Pplat), mean pressure (Pmean), FiO2 (15-100%), breathing rate (spontaneous/set), I:E ratio, P-T/Flow-T/V-T waveforms, P-V/F-V loops |
| Alarm System | 3-level color-coded audible-visual alarm; alarm events: high/low pressure, high/low tidal volume, high/low ventilation volume, high/low FiO2, high/low PEEP, high/low frequency, apnea (3-20s adjustable), low drive gas pressure (<280kPa), low battery (8±0.2V); alarm volume: 2-10 |
| Display & Operation | 9-inch HD TFT touchscreen; shuttle knob; lock screen function; mute key (120s mute); weight-based auto-parameter calculation |
| Power Supply | AC power + built-in lithium battery (2-4 hours of backup) |
| Safety & Reliability | ISO13485/CE certified; cooling fan system; grounding protection; 36-month warranty |
| Compatibility | International standard interface; compatible with all standard veterinary anesthesia machines |
| Dimensions & Portability | Compact, lightweight design; easy to move; suitable for fixed and mobile use |

