BPU200 Shear Wave Ultrasound Diagnostic System – Liver Fibrosis Staging, Tumor Qualitative Diagnosis & Dynamic Health Monitoring

BPU200 is China’s first professional shear wave ultrasound diagnostic system dedicated to liver health. Equipped with patented shear wave elastography, high-resolution 2D imaging, and real-time dynamic blood flow visualization, it delivers accurate liver fibrosis staging (F0-F4), tumor qualitative diagnosis, and dynamic treatment monitoring. Backed by 25 patents, the system ensures reliable, reproducible quantitative results to reduce misdiagnosis. With DICOM compatibility, specialized software, and a user-friendly design, it supports full-cycle liver health management—from early detection to treatment tracking. Ideal for hospitals, liver clinics, and examination centers, it’s a powerful tool for clinicians seeking precise, efficient liver assessment solutions.

Description

The SonoMaxx BPU200 Shear Wave Ultrasound Diagnostic System is China’s first professional ultrasound system dedicated exclusively to liver health assessment. Engineered by SonoMaxx Medical Technology Co., Ltd., this cutting-edge device integrates patented shear wave elastography technology, high-resolution imaging, and intelligent quantitative analysis to deliver a full-cycle visualization and quantitative diagnostic solution—from early liver lesion detection to treatment tracking. Designed for hospitals, liver specialty clinics, and physical examination centers, the BPU200 addresses the critical challenge of hidden early liver diseases (e.g., fatty liver, fibrosis) by providing accurate, reproducible assessments of liver stiffness and tissue elasticity. With a suite of 25 patents (covering core technologies like shear wave imaging, filtering, and speed detection) and specialized software, it supports liver fibrosis staging, tumor qualitative diagnosis, and dynamic health monitoring—empowering clinicians to make confident decisions, reduce misdiagnosis, and optimize patient care. Whether for routine screenings, clinical diagnosis, or treatment response evaluation, the BPU200 redefines liver ultrasound with precision, efficiency, and user-centric design.

Core Product Advantages

Patented Shear Wave Elastography for Precise Liver Fibrosis Staging

At the heart of the BPU200 is its proprietary shear wave elastography technology, backed by multiple core patents :

  1. Quantitative Liver Stiffness Measurement: Delivers objective, numerical values of liver stiffness to accurately grade fibrosis stages (F0-F4), overcoming the limitations of subjective visual assessment. The technology ensures excellent reproducibility, enabling consistent tracking of disease progression or regression over time.
  2. Advanced Shear Wave Processing: Features patented direction filtering, dynamic filtering, and elasticity image quality evaluation to minimize noise and enhance the clarity of shear wave propagation, ensuring reliable results even in complex clinical scenarios.

High-Quality Imaging & Comprehensive Diagnostic Capabilities

  1. High-Resolution 2D Imaging: Equipped with a broadband, high-penetration probe that delivers sharp, detailed 2D images of liver parenchyma, enabling early detection of subtle lesions (e.g., small tumors, fatty infiltration) that may be missed by conventional ultrasound.
  2. Real-Time Dynamic Blood Flow Visualization: Clearly displays hepatic blood flow dynamics, supporting the assessment of vascular involvement in liver diseases (e.g., cirrhosis-related portal hypertension, tumor angiogenesis).
  3. Tumor Qualitative Diagnosis: Enhances the differentiation of benign and malignant liver nodules, reducing unnecessary surgical interventions and biopsy procedures—improving patient outcomes and reducing healthcare costs.

Full-Cycle Liver Health Management

The BPU200 supports a comprehensive range of clinical applications across the liver disease management continuum:

  1. Early Detection: Identifies asymptomatic fatty liver and early-stage fibrosis, enabling timely lifestyle or medical intervention to prevent progression to cirrhosis or liver cancer.
  2. Treatment Tracking: Provides dynamic monitoring of liver health during anti-fibrotic therapy or tumor intervention, offering visual and quantitative data to evaluate treatment efficacy.
  3. Routine Screening: Ideal for physical examination centers and primary care settings to screen high-risk populations (e.g., chronic hepatitis patients, obese individuals, heavy drinkers).

Intelligent Software & Seamless Workflow Integration

  1. Specialized Software Suite: Includes dedicated software for liver measurement, patient record management, DICOM middleware, and user interaction—streamlining clinical workflow from image acquisition to report generation.
  2. DICOM Compatibility: Supports integration with hospital PACS systems, enabling easy data sharing, archiving, and remote consultation.
  3. User-Friendly Design: Features an intuitive interface, efficient operation logic, and auxiliary functions (e.g., probe protection 套,chassis panel extraction aid) to enhance usability and device durability.

Reliable Performance Backed by Innovation

  1. Extensive Patent Portfolio: 25 patents covering core technologies, hardware design, and software systems—validating its technical superiority and innovation.
  2. Robust Hardware: Equipped with advanced components such as EMI filtering circuits, automatic voltage regulation, and efficient heat dissipation—ensuring stable performance in long-term clinical use.
  3. Clinical Confidence: Reduces misdiagnosis and missed diagnosis risks through objective quantitative data, empowering clinicians with stronger diagnostic confidence and supporting evidence-based medicine.
Specification Category Parameter Details
Product Model SonoMaxx BPU200 Shear Wave Ultrasound Diagnostic System
Core Application Liver health assessment: liver fibrosis staging (F0-F4), fatty liver detection, liver tumor qualitative diagnosis, dynamic treatment monitoring
Key Imaging Technologies – Core Technology: Shear wave elastography (patented)- 2D Imaging: High-resolution, broadband high-penetration probe- Blood Flow Imaging: Real-time dynamic blood flow visualization- Patented Features: Shear wave direction filtering, dynamic filtering, elasticity image quality evaluation, shear wave speed detection
Diagnostic Capabilities – Liver Fibrosis Staging: Quantitative stiffness measurement, F0-F4 grading- Tumor Diagnosis: Benign/malignant nodule differentiation- Dynamic Monitoring: Anti-fibrotic treatment efficacy tracking, fatty liver progression curve- Additional: Early lesion detection, vascular assessment
Software & Compatibility – Software Suite: Liver measurement software, patient record management software, DICOM middleware, emission control software, data acquisition control software- Compatibility: DICOM compliant, PACS integration support- User Interface: Intuitive user interaction system
Hardware & Design – Probe: Broadband high-penetration ultrasound probe- Protective Features: Probe protective cover, chassis panel extraction aid- Power & Stability: Automatic voltage regulation circuit, EMI filtering circuit, efficient heat dissipation device- Patents: 25 patents (core technology, hardware, software, 著作权)
Clinical Application Scenarios Hospitals, liver specialty clinics, physical examination centers, primary care facilities